A lattice column places steel where it works and leaves the middle empty. Two or four legs carry the axial load at the corners of a large section, while lacing or batten plates hold them together. The result is a column with the bending stiffness of a much deeper solid member, at a fraction of the weight.
Bending capacity depends on how far the material sits from the neutral axis, not on how much material there is. A solid web column of the same overall depth would carry the same moment, but most of its web would be doing very little.
The void does three more things:
Lacing is not a connector. Once the column bends, the legs try to move relative to each other, and the lacing resists that movement. The shear in the lacing comes from the column shear plus the shear from any imperfection, and it is the reason a laced column is designed as a system rather than as separate members.
That is also why a battened column and a laced column of the same overall size are not interchangeable. The battened version relies on frame action between the battens, so the battens and their connections see larger local forces.
A built-up column has two slenderness values that matter: the whole member about each axis, and a single leg between points of connection. The second one is easy to forget and expensive to get wrong — a leg that is too slender buckles locally, and the column fails well below its calculated capacity.
In Chinese practice the design uses an equivalent slenderness that combines the two. EN 1993-1-1 handles built-up members in its own clause and applies an imperfection of L/500 instead of the L/200 used for a solid member. AISC 360 has its own provisions. The three codes agree on the principle and differ in the arithmetic, which is why the standard has to be named before the column is sized.
Four things decide whether a lattice column arrives straight and fits on site.
A 12 m lattice column at 1.2 m centres occupies the volume of a small room. Shipped assembled, one column can take the space of six tonnes of ordinary beams.
The normal route is to send the legs as bundles and the lacing as a separate crate, with a match-marked erection drawing. Site assembly is bolted where the design allows, or welded under the same procedure used in the factory. Both are cheaper than paying for air.
For a primary member we issue the material certificates to EN 10204 3.1, the dimensional record, the straightness record and the weld inspection report. Where the column is fatigue-loaded or part of a crane structure, ultrasonic testing on the leg-to-batten and leg-to-diaphragm welds is specified at enquiry stage.
| Requirement | Details |
|---|---|
| Column schedule | Overall depth, leg spacing, length, and the number of columns |
| Leg section | Leg section, or the required axial load and moment |
| Configuration | Laced or battened, and the lacing pattern if it is drawn |
| Grade | Q235B, Q355B, or S355JR / A572 Gr.50 equivalent |
| Execution standard | GB 50017, EN 1993-1-1 or AISC 360 |
| Surface | Primed or galvanized; fire protection if specified |
| Site connection | Bolted or welded |
Send these and we return the fabrication drawing, the weight and a quotation.
When the column is long, heavily loaded, and bending stiffness matters more than simplicity. Above roughly 10 m, or where the column also carries crane loads, the weight saved starts to pay for the extra fabrication.
Lacing uses diagonal bars and behaves closer to a truss; battens use parallel plates and behave closer to a frame. Lacing is more efficient in shear, battens are cheaper to fabricate. They are not interchangeable without re-checking the design.
Too shallow and the lacing carries a large force for a small shear; too steep and it stops acting as a truss. Chinese practice keeps it between about 40° and 70° to the column axis.
It can, but it is expensive. Most lattice columns ship as legs plus a lacing crate with match-marked drawings, and are assembled on site.
Yes. The void makes galvanizing easier than on a box column, because there is no sealed compartment — but drain and vent holes still have to be drilled at the design stage.
GB 50017, EN 1993-1-1 or AISC 360, as the project names. The three treat built-up members differently, so the standard is fixed before the section is sized.
Yes — match-marked, with the leg and lacing identification, the bolt list and the sequence.
Send the column schedule and the standard.
We return the fabrication drawing, the weight and a quotation.