Products
PRODUCTS DETAILS
Home > Products >
40m Clear Span Column Free Steel Warehouse with Q355B Steel Grade and 50 Years Using Life PEB Steel Structure

40m Clear Span Column Free Steel Warehouse with Q355B Steel Grade and 50 Years Using Life PEB Steel Structure

MOQ: 1 PCS/20 Tons
Price: $1300-3000
Standard Packaging: Customized based on project
Delivery Period: 30-60 Days
Payment Method: L/C,D/A,D/P,T/T
Supply Capacity: 15,000 t / month
Detail Information
Place of Origin
Chengdu , China
Brand Name
Sichuan Shunyao Supply Chain Management Co., Ltd.
Certification
CE,ISO
Spanwidth:
Up To 60 Meters
Steel Grade:
Q355B/ Q235B
Walltype:
Steel Panel/Insulated Panel/Brick
Coating Type:
Anti-corrosion Paint
Maintenance Costs:
Reduced
Roof Sheet:
AZ150 Steel Sheet With Internal Ceiling
Using Life:
50 Years
Feature:
Easy To Assemble&dismentle
Span Width:
Up To 30 Meters
Length:
Flexible, Based On Customer Requirements
Doors:
Roll-up Or Sliding Steel Doors
Window:
PVC Or Aluminum Alloy
Thickness Range:
0.3mm - 6.0mm
Span Range:
Up To 30 Meters Without Internal Columns
Building Height:
4-12 Meters
Highlight:

Column Free PEB Steel Warehouse

,

40m Clear Span PEB Steel Warehouse

,

50 Years Life PEB Steel Warehouse

Product Description

A column-free steel warehouse with a clear span of up to 40 m removes internal columns entirely, turning the whole floor into usable, racking-ready space. Built with Q235B / Q355B steel and A572 Gr.50 channels in a bolted frame, it is engineered for distribution, logistics, and any operation where the layout must stay flexible.

  • Clear span to 40 m
  • Q235B / Q355B steel
  • A572 Gr.50 channels
  • Bolted frame assembly
Why a Clear Span Pays for Itself

In a column-free warehouse, a column is a cost you pay twice: once to build, and once every day — in the aisle that has to go around it and the racking bay that cannot be where the layout wants it. A clear span of 30 m to 40 m removes the internal columns altogether, and the whole floor becomes usable.

What the Operator Actually Gets
  • Straight forklift routes. No weaving between posts, no blind corners where a truck meets a column.
  • Racking laid out for density, not for the structure. Bay widths are set by the pallet and the truck, not by a 6 m column grid.
  • Loading doors anywhere along the elevation. No column line dictates where a dock can be cut.
  • A floor plan that can change later. A tenant moves out, the layout is re-planned, and the building does not become the constraint.

Those four points are why a clear span is worth paying for in a distribution building. They are not worth paying for in a building that only stores pallets against the walls.

What 40 m Does to the Structure

In a column-free warehouse the rafter spans 40 m, and that is not a 20 m rafter made longer. The bending moment rises with the square of the span, so the section depth and the steel weight per square metre climb steeply after about 30 m.

Three consequences follow, and they should be priced in from the start:

  • Deeper rafters, which raises the eave height needed for the same clear height — and therefore the cladding area.
  • Heavier columns and base plates, because the same load arrives at fewer supports.
  • A transport problem: a 40 m rafter does not fit in anything, so it is spliced at a designed point and shipped in pieces.

A supplier who quotes a 40 m building at the 20 m rate per square metre has either misread the drawing or intends to change the section later.

Secondary Framing That Does Real Work at This Span

At long spans the purlins and secondary members stop being minor items. Where the design calls for it, we use American standard channels to ASTM A572 Gr.50 — for example C9×134, a 9 inch channel at 134 lb/ft — as high-capacity members, with C and Z purlins in Q235B elsewhere, and knee braces, tie tubes and round-bar bracing completing the system.

We quote weights per metre on the sections we propose, so the freight and customs figures are known before the order rather than after.

Where a Column-Free Warehouse Suits

Distribution and logistics buildings are the main case. It also suits dust-controlled workshops, ESD-controlled assembly areas, food and chemical processing halls, heavy industry and high-voltage plant buildings, and research facilities — anywhere the floor has to stay free of obstruction or the internal layout has to remain flexible.

Where Long-Span Steel Needs Care

Steel is the right material at this span, but three things have to be specified rather than assumed.

Consideration Requirement
Fire Bare steel loses strength when hot. Where the code requires a period of fire resistance, the columns and rafters need a coating or a board — a real cost per square metre of surface.
Corrosion Humid, coastal or chemical sites need a proper coating system or galvanizing, not a thin paint film. The coating is chosen for the corrosivity category, and the thickness is specified as a number.
Low temperature Cold sites need a grade with tested impact toughness — S355J2 rather than S355JR — and that has to be decided before the mill order, not after.

We raise these at quotation stage. If the site is coastal or very cold, say so at the start and the specification changes accordingly.

Cut and Drilled, So the Site Is Assembly

Members are supplied cut to length and drilled to the shop drawing, with the rafter splices, base plates and purlin cleats already in place. Site work becomes bolting rather than fabrication, which matters when the erection crew is small and the weather window is short.

What We Need to Quote
  • Clear span required, and the building length
  • Clear height, and the eave height that follows from it
  • Floor loading and the racking layout, if it is known
  • Number and size of loading doors
  • Site loads: wind, snow, seismic, and whether the site is coastal
  • Roof and wall build-up, and whether insulation is required
  • Any special requirement: dust control, ESD, fire resistance

Send these and we return the column grid, the section sizes, the weight and a quotation.

Frequently Asked Questions
What is the maximum clear span?

40 m with a portal frame and a deeper rafter. Beyond that a truss or a multi-span arrangement with an internal column is usually cheaper than a heavier single span.

Is a column-free warehouse more expensive?

Per square metre, yes — the rafter is deeper and the foundation carries more load at fewer points. Whether it is worth it depends on the racking layout and the handling speed, which is what the clear span is buying.

Can the building be extended later?

Yes, if the end frame is designed for it. Tell us at enquiry stage and the columns, foundation and cladding junction are detailed for a future bay.

Can it carry a crane?

Not as a standard clear-span warehouse. A crane needs a runway beam, heavier columns and a fatigue check, which is a different structural system — see the crane beam workshop page.

How is a 40 m rafter shipped?

In two pieces, spliced at a designed point with a bolted end-plate connection, shipped in 40 ft open-top containers or as break-bulk. The splice position is set with the transport route.

Do you supply the racking?

No. We design the building around the racking layout you provide. Sending the racking drawing at enquiry stage is the fastest way to get a column grid that works.

What about fire protection?

Columns and rafters are protected to the rating your code requires, with intumescent coating or board. We issue the member schedule and the required thickness for approval before production.

Send the span, the clear height and the racking layout for your column-free warehouse. We return the column grid, the section sizes and a quotation.